Component |
Possible Cause |
Remedy / Check |
a. Collector panel |
-
Partially shaded
-
Improper Orientation
-
Improper tilt
-
Improperly plumbed
-
Dirty glazing
-
Leakage
|
-
Reduce shading or relocate collector panels
-
Check direction; South is the best direction. North is not suggested.
-
Check tilt; set equal to latitude ±15°
-
Check connection from collector to storage. Joint at storage tank must not be at same level or lower than collector.
-
Clean collector panel’s surface.
-
Replace the collector panel
|
b. Piping |
-
Nighttime thermosiphoning (circulation pump only)
-
Leakage
|
-
Check for pump running at night time. Contact installers.
-
Tighten leaking spot
|
c. Storage tank |
-
Insufficient size / over usage
-
High storage losses
-
Leakage
|
-
Check mixer tap. Possibility of consuming hot water without realising.
-
Check tank insulation
-
Replace the storage tank
|